How to reduce downtime on long land and submarine cables and pinpoint cable faults ‌ ‌ ‌ ‌ ‌ ‌ ‌ ‌ ‌ ‌ ‌ ‌ ‌ ‌ ‌ ‌ ‌ ‌ ‌ ‌ ‌ ‌ ‌ ‌ ‌ ‌ ‌ ‌ ‌ ‌  ‌ ‌ ‌ ‌ ‌ ‌ ‌ ‌ ‌ ‌ ‌ ‌ ‌ ‌ ‌ ‌ ‌ ‌ ‌ ‌ ‌ ‌ ‌ ‌ ‌ ‌ ‌ ‌ ‌ ‌  ‌ ‌ ‌ ‌ ‌ ‌ ‌ ‌ ‌ ‌ ‌ ‌ ‌ ‌ ‌ ‌ ‌ ‌ ‌ ‌ ‌ ‌ ‌ ‌ ‌ ‌ ‌ ‌ ‌ ‌  ‌ ‌ ‌ ‌ ‌ ‌ ‌ ‌ ‌ ‌ ‌ ‌ ‌ ‌ ‌ ‌ ‌ ‌ ‌ ‌ ‌ ‌ ‌ ‌ ‌ ‌ ‌ ‌ ‌ ‌  ‌ ‌ ‌ ‌ ‌ ‌ ‌ ‌ ‌ ‌ ‌ ‌ ‌ ‌ ‌ ‌ ‌ ‌ ‌ ‌ ‌ ‌ ‌ ‌ ‌ ‌ ‌ ‌ ‌ ‌
Open in Browser

XL Cable Fault Location  

Long cables. Precise cable fault location.

Dear , 
 
Long land and submarine cables are a vital part of the energy supply. If a cable fault occurs, prolonged downtime can result in high costs. This makes it all the more important to be prepared for such events.  
 
BAUR has been developing bespoke solutions for cable fault location in long land and submarine cables for over 15 years. Specially tailored cable fault location systems enable rapid and precise fault location – even in very long cable systems.

Overview of the advantages:

■Reduce downtime: Suitable fault location systems can be deployed immediately in the event of a fault.
 
■Pinpoint cable faults: Depending on the measurement method, measurement accuracies with deviations of between 0.05% and 1% of the cable length can be achieved.
■Improve safety: Specially designed systems enable the safe discharge of stored energy, even with long cables.
 
■Stay flexible: BAUR offers portable devices, mobile systems and stationary XL-CFL systems to meet different requirements.
 
Particularly with very long cables, taking measurements at both ends of the cable can improve the accuracy of the cable fault pre-location and save valuable time during the early stages of the fault location process. 
 

A case study: Fault location on a 300 km submarine cable

An operation in Australia illustrates just how important experience and the right measurement technology are when dealing with very long cables: Following a fault on a 300 km-long 400 kV submarine cable between south-eastern Australia and Tasmania, BAUR expert Manfred Bawart assisted with fault location. By combining TDR measurements with Murray bridge measurements, the fault was located quickly and with a high degree of accuracy.
Read the expert interview

New team in the XL-CFL centre of competence

Andreas Freis: 

 
■25 years of practical experience in cable fault location, cable testing and diagnostics
■Project management for international bespoke solutions
■Extensive experience in the field of training and seminars

Matthias Zimmermann: 

 
■5 years of practical experience in cable fault location, cable testing and diagnostics
■Project management for international bespoke solutions
■Managing XL-CFL projects for Italy for the past 5 years
If you have any questions about XL cable fault location, the BAUR experts are on hand to assist you personally. We will work with you to assess your specific requirements and help you find the right solution for your cable system and your particular application.
Discover BAUR solutions for XL cable fault location
Yours sincerely, 
BAUR Team 
 
© BAUR GmbH | Raiffeisenstraße 8 | 6832 Sulz I Austria
Open in browser
Unsubscribe